Summary of Study ST001950

This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR001237. The data can be accessed directly via it's Project DOI: 10.21228/M8TB0S This work is supported by NIH grant, U2C- DK119886.

See: https://www.metabolomicsworkbench.org/about/howtocite.php

Perform statistical analysis  |  Show all samples  |  Show named metabolites  |  Download named metabolite data  
Download mwTab file (text)   |  Download mwTab file(JSON)   |  Download data files (Contains raw data)
Study IDST001950
Study TitleLipidome Alterations Following Mild Traumatic Brain Injury.
Study TypeUntargeted Lipidomics
Study SummaryTraumatic brain injury (TBI) poses a major health challenge, with tens of millions of new cases reported globally every year. Brain damage resulting from TBI can vary significantly due to factors including injury severity, diffusivity, modality, time delay relative to impact, and exposure to repeated injury events. Untargeted lipidomic analysis of Sprague-Dawley rat serum within 24 hours of mild single and repeat controlled cortical impact (CCI) injury events led to the discovery of biomarker candidates of TBI. Lipid biomarkers have a unique potential to serve as objective molecular measures of the body’s response to injury as their alteration in brain tissue can be more freely observed than for larger protein markers. Animal serum was analyzed via ultra-high-performance liquid chromatography-mass spectrometry (UHPLC-MS) in positive and negative ion modes. Known lipid species were identified through matching to in-house tandem MS databases. Machine learning and feature selection approaches were used to construct lipid panels capable of distinguishing serum from injured and uninjured animals across a range of injury severities and timepoints within the first day of injury. The best multivariate lipid panels had over 90% cross-validated sensitivity, selectivity, and accuracy and consisted of species from nine different lipid classes. These mapped onto sphingolipid signaling, autophagy, necroptosis and glycerophospholipid metabolism pathways, with FDR corrected p-values better than 0.05.
Institute
Georgia Institute of Technology
DepartmentChemistry and Biochemistry
LaboratoryFacundo Fernández
Last NameGier
First NameEric
Address311 Ferst Drive, Atlanta, GA, 30318, USA
Emailegier3@gatech.edu
Phone2246221699
Submit Date2021-10-24
Num Groups6
Total Subjects32
Num Males14
Num Females18
Study CommentsLC-MS
Raw Data AvailableYes
Raw Data File Type(s)mzML
Analysis Type DetailLC-MS
Release Date2022-02-07
Release Version1
Eric Gier Eric Gier
https://dx.doi.org/10.21228/M8TB0S
ftp://www.metabolomicsworkbench.org/Studies/ application/zip

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN003174 AN003175
Analysis type MS MS
Chromatography type Reversed phase Reversed phase
Chromatography system Thermo Vanquish Thermo Vanquish
Column Thermo Accucore C30 (50 x 2.1mm,2.1um) Thermo Accucore C30 (50 x 2.1mm,2.1um)
MS Type ESI ESI
MS instrument type Orbitrap Orbitrap
MS instrument name Thermo ID-X Orbitrap Tribrid Thermo ID-X Orbitrap Tribrid
Ion Mode POSITIVE NEGATIVE
Units Normalized Peak Area Normalized Peak Area

MS:

MS ID:MS002952
Analysis ID:AN003174
Instrument Name:Thermo ID-X Orbitrap Tribrid
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:MS experiments were preformed over a scan range of 150-2000 m/z, maximum ion injection time was set to 200 ms, and orbitrap resolution was 24000. Raw spectral data from LC-MS experiments were pre-processed using Compound Discoverer v3.0.0 software (Thermo Fischer Scientific, Inc., Waltham, MA) and the XCMS web-based application (xcmsonline.scripps.edu). Initial steps involved retention time alignment between samples, peak area integration, peak picking, and QC area normalization. Features eluting with the solvent front or having retention times below 0.75 min were removed to account for potential ion suppression effects in that retention time region. ChemSpider and in-house mzVault database searches were used to obtain a list of tentative IDs based on accurate mass, isotope pattern, and MS/MS data whenever possible. Each lipid feature was identified according to the following confidence levels: (1) compounds matched to existing in house database standards by accurate mass (<2 ppm), isotopic abundance, fragmentation spectrum, and retention time; (2) compounds annotated according to accurate mass, isotopic abundance, and fragmentation consistent with Lipid Maps and Human Metabolome Database (HMDB) entries; (3) accurate mass match matched to Lipid Maps and HMDB entries and fragmentation showing a few matching characteristic fragment ions.
Ion Mode:POSITIVE
Ion Source Temperature:275 ℃
Ion Spray Voltage:3500 V
Source Temperature:320 ℃
  
MS ID:MS002953
Analysis ID:AN003175
Instrument Name:Thermo ID-X Orbitrap Tribrid
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:MS experiments were preformed over a scan range of 150-2000 m/z, maximum ion injection time was set to 200 ms, and orbitrap resolution was 24000. Raw spectral data from LC-MS experiments were pre-processed using Compound Discoverer v3.0.0 software (Thermo Fischer Scientific, Inc., Waltham, MA) and the XCMS web-based application (xcmsonline.scripps.edu). Initial steps involved retention time alignment between samples, peak area integration, peak picking, and QC area normalization. Features eluting with the solvent front or having retention times below 0.75 min were removed to account for potential ion suppression effects in that retention time region. ChemSpider and in-house mzVault database searches were used to obtain a list of tentative IDs based on accurate mass, isotope pattern, and MS/MS data whenever possible. Each lipid feature was identified according to the following confidence levels: (1) compounds matched to existing in house database standards by accurate mass (<2 ppm), isotopic abundance, fragmentation spectrum, and retention time; (2) compounds annotated according to accurate mass, isotopic abundance, and fragmentation consistent with Lipid Maps and Human Metabolome Database (HMDB) entries; (3) accurate mass match matched to Lipid Maps and HMDB entries and fragmentation showing a few matching characteristic fragment ions.
Ion Mode:NEGATIVE
Ion Source Temperature:275 ℃
Ion Spray Voltage:-2500 V
Source Temperature:320 ℃