Summary of Study ST002200

This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR001403. The data can be accessed directly via it's Project DOI: 10.21228/M8C99T This work is supported by NIH grant, U2C- DK119886.

See: https://www.metabolomicsworkbench.org/about/howtocite.php

This study contains a large results data set and is not available in the mwTab file. It is only available for download via FTP as data file(s) here.

Perform statistical analysis  |  Show all samples  |  Show named metabolites  |  Download named metabolite data  
Download mwTab file (text)   |  Download mwTab file(JSON)   |  Download data files (Contains raw data)
Study IDST002200
Study TitleHuman Trisome Project Plasma Metabolomics v1
Study SummaryAnalysis of metabolite relative abundance in blood plasma from 316 individuals with trisomy 21 (T21, Down syndrome) and 103 euploid controls. This dataset is part of the Human Trisome Project run by the Linda Crnic Institute for Down Syndrome at the University of Colorado Anschutz Medical Campus. http://www.trisome.org/
Institute
University of Colorado Denver
LaboratoryPIs - Joaquin Espinosa and Angelo D'Alessandro
Last NameHaines
First NameJulie
Address12801 E 17th Ave, Room 1303, Aurora, Colorado, 80045, USA
Emailjulie.haines@cuanschutz.edu
Phone3037243339
Submit Date2022-06-15
Num Groups2
Total Subjects419
Raw Data AvailableYes
Raw Data File Type(s)raw(Thermo)
Analysis Type DetailLC-MS
Release Date2023-06-15
Release Version1
Julie Haines Julie Haines
https://dx.doi.org/10.21228/M8C99T
ftp://www.metabolomicsworkbench.org/Studies/ application/zip

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN003600 AN003601 AN003602 AN003603
Analysis type MS MS MS MS
Chromatography type Reversed phase Reversed phase Reversed phase Reversed phase
Chromatography system Thermo Vanquish Thermo Vanquish Thermo Vanquish Thermo Vanquish
Column Phenomenex Kinetex C18 (150 x 2.1mm,1.7um) Phenomenex Kinetex C18 (150 x 2.1mm,1.7um) Waters ACQUITY HSS T3 (150 x 2.1mm,1.8um) Waters ACQUITY HSS T3 (150 x 2.1mm,1.8um)
MS Type ESI ESI ESI ESI
MS instrument type Orbitrap Orbitrap Orbitrap Orbitrap
MS instrument name Thermo Q Exactive Orbitrap Thermo Q Exactive Orbitrap Thermo Q Exactive Orbitrap Thermo Q Exactive Orbitrap
Ion Mode NEGATIVE POSITIVE NEGATIVE POSITIVE
Units peak area peak area peak area peak area

MS:

MS ID:MS003355
Analysis ID:AN003600
Instrument Name:Thermo Q Exactive Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:Resolution 70,000, scan range 65-900 m/z, maximum injection time 200 ms, microscans 2, automatic gain control (AGC) 3 x 10^6 ions, source voltage 4.0 kV, capillary temperature 320 C, and sheath gas 45, auxiliary gas 15, and sweep gas 0 (all nitrogen). Data converted to mzXML using RawConverter. Metabolites were annotated and integrated using Maven in conjunction with the KEGG database.
Ion Mode:NEGATIVE
  
MS ID:MS003356
Analysis ID:AN003601
Instrument Name:Thermo Q Exactive Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:Resolution 70,000, scan range 65-900 m/z, maximum injection time 200 ms, microscans 2, automatic gain control (AGC) 3 x 10^6 ions, source voltage 4.0 kV, capillary temperature 320 C, and sheath gas 45, auxiliary gas 15, and sweep gas 0 (all nitrogen). Data converted to mzXML using RawConverter. Metabolites were annotated and integrated using Maven in conjunction with the KEGG database.
Ion Mode:POSITIVE
  
MS ID:MS003357
Analysis ID:AN003602
Instrument Name:Thermo Q Exactive Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:Resolution 70,000, scan range 150-1500 m/z, maximum injection time 200 ms, microscans 2, automatic gain control (AGC) 3 x 10^6 ions, source voltage 4.0 kV, capillary temperature 320 C, and sheath gas 45, auxiliary gas 15, and sweep gas 0 (all nitrogen). Data converted to mzXML using RawConverter. Metabolites were annotated and integrated using Maven in conjunction with the KEGG database.
Ion Mode:NEGATIVE
  
MS ID:MS003358
Analysis ID:AN003603
Instrument Name:Thermo Q Exactive Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:Resolution 70,000, scan range 150-1500 m/z, maximum injection time 200 ms, microscans 2, automatic gain control (AGC) 3 x 10^6 ions, source voltage 4.0 kV, capillary temperature 320 C, and sheath gas 45, auxiliary gas 15, and sweep gas 0 (all nitrogen). Data converted to mzXML using RawConverter. Metabolites were annotated and integrated using Maven in conjunction with the KEGG database.
Ion Mode:POSITIVE
  logo