Summary of Study ST001660

This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR001065. The data can be accessed directly via it's Project DOI: 10.21228/M81Q3K This work is supported by NIH grant, U2C- DK119886.

See: https://www.metabolomicsworkbench.org/about/howtocite.php

This study contains a large results data set and is not available in the mwTab file. It is only available for download via FTP as data file(s) here.

Perform statistical analysis  |  Show all samples  |  Show named metabolites  |  Download named metabolite data  
Download mwTab file (text)   |  Download mwTab file(JSON)   |  Download data files (Contains raw data)
Study IDST001660
Study TitlePlasmodium falciparum metabolomics as a result of treatment with putative acetyl-CoA synthetase inhibitors
Study SummaryPlasmodium falciparum cells in culture were treated with respective compounds for 2.5 hours at 10xIC50 values. Metabolites were isolated using 90% methanol, dried, reconstituted in HPLC-grade water, and analyzed by HPLC/MS. Resulting data were analyzed and compiled to generate study data.
Institute
Pennsylvania State University
DepartmentChemistry
LaboratoryLlinás Laboratory
Last NameLlinás
First NameManuel
AddressW126 Millennium Science Complex, University Park, PENNSYLVANIA, 16802, USA
Emailmul27@psu.edu
Phone814-867-3444
Submit Date2021-01-22
Num Groups3
Total Subjects24
Raw Data AvailableYes
Raw Data File Type(s)mzXML
Analysis Type DetailLC-MS
Release Date2021-06-01
Release Version1
Manuel Llinás Manuel Llinás
https://dx.doi.org/10.21228/M81Q3K
ftp://www.metabolomicsworkbench.org/Studies/ application/zip

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN002711
Analysis type MS
Chromatography type Reversed phase
Chromatography system Thermo Dionex Ultimate 3000
Column Waters XSelect HSS (100 x 2.1mm,2.5um)
MS Type ESI
MS instrument type Orbitrap
MS instrument name Thermo Q Exactive Plus Orbitrap
Ion Mode NEGATIVE
Units Normalized and blank subtracted peak area

Chromatography:

Chromatography ID:CH002000
Chromatography Summary:Ion-pairing method using reverse-phase chromatography setup.
Instrument Name:Thermo Dionex Ultimate 3000
Column Name:Waters XSelect HSS (100 x 2.1mm,2.5um)
Column Temperature:30
Solvent A:97% water/3% methanol; 15 mM acetic acid; 10 mM tributylamine
Solvent B:100% methanol
Chromatography Type:Reversed phase