Summary of Study ST002550

This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR001642. The data can be accessed directly via it's Project DOI: 10.21228/M8FX54 This work is supported by NIH grant, U2C- DK119886.

See: https://www.metabolomicsworkbench.org/about/howtocite.php

This study contains a large results data set and is not available in the mwTab file. It is only available for download via FTP as data file(s) here.

Perform statistical analysis  |  Show all samples  |  Show named metabolites  |  Download named metabolite data  
Download mwTab file (text)   |  Download mwTab file(JSON)   |  Download data files (Contains raw data)
Study IDST002550
Study TitleTargeted metabolomics for ARDS
Study SummaryAcute respiratory distress syndrome (ARDS) is a heterogeneous disease in its etiology and clinical aspects, and it has been an important interest in how to diagnose it and classify its subtypes, and apply them to treatment. Metabolomics is becoming important for identifying ARDS biology and distinguishing subtypes. The aim of this study is to identify metabolites distinguishing sepsis-induced ARDS patients from healthy controls using a targeted metabolomics approach, and to find out whether direct and indirect ARDS are metabolically distinct groups and confirm their metabolites and associated pathways. Targeted metabolomics was performed to explore metabolome changes between pARDS (pediatric ARDS) and eARDS.
Institute
Asan Medical Center
Last NameYoo
First NameHyun Ju
Address88, Olympic-ro 43-gil, Songpa-gu
Emailyoohyunju@amc.seoul.kr
Phone0230104029
Submit Date2023-03-30
Raw Data AvailableYes
Raw Data File Type(s)mzML
Analysis Type DetailLC-MS
Release Date2023-07-06
Release Version1
Hyun Ju Yoo Hyun Ju Yoo
https://dx.doi.org/10.21228/M8FX54
ftp://www.metabolomicsworkbench.org/Studies/ application/zip

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN004198 AN004199
Analysis type MS MS
Chromatography type Reversed phase Reversed phase
Chromatography system Agilent 1290 Agilent 1290
Column Agilent ZORBAX Eclipse Plus C18 (50 x 2.1mm,1.8um) Agilent Pursuit 5 C18 (150 x 2.1mm,5um)
MS Type ESI ESI
MS instrument type QTRAP QTRAP
MS instrument name ABI Sciex 5500 QTrap ABI Sciex 5500 QTrap
Ion Mode POSITIVE POSITIVE
Units nM nM

MS:

MS ID:MS003945
Analysis ID:AN004198
Instrument Name:ABI Sciex 5500 QTrap
Instrument Type:QTRAP
MS Type:ESI
MS Comments:Data analysis was performed using Analyst 1.5.2 software. Extracted ion chromatograms (EIC) corresponding to each metabolite were used for quantitation (MRM). The area under the curve of each EIC was normalized to that of the internal standard. For metabolites related to PC/PE profiling, the peak area ratio of each metabolite to that of the internal standard was used for a relative comparison. For plasmalogens, the calibration range was generally 0.1 nM to 10 μM with R2>0.99
Ion Mode:POSITIVE
  
MS ID:MS003946
Analysis ID:AN004199
Instrument Name:ABI Sciex 5500 QTrap
Instrument Type:QTRAP
MS Type:ESI
MS Comments:Data analysis was performed using Analyst 1.5.2 software. Extracted ion chromatograms (EIC) corresponding to each metabolite were used for quantitation (MRM). The area under the curve of each EIC was normalized to that of the internal standard. For ceramides and sphingomyelins, the calibration range was generally 0.1 nM to 10 μM with R2>0.99
Ion Mode:POSITIVE
  logo