Summary of Study ST002968

This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR001847. The data can be accessed directly via it's Project DOI: 10.21228/M8ZT64 This work is supported by NIH grant, U2C- DK119886.

See: https://www.metabolomicsworkbench.org/about/howtocite.php

This study contains a large results data set and is not available in the mwTab file. It is only available for download via FTP as data file(s) here.

Perform statistical analysis  |  Show all samples  |  Show named metabolites  |  Download named metabolite data  
Download mwTab file (text)   |  Download mwTab file(JSON)   |  Download data files (Contains raw data)
Study IDST002968
Study TitleUntargeted metabolomic studies of the PSD95-nNOS uncoupling agent against post-stroke depression in rats
Study Typeresearch
Study SummaryTo elucidate the antidepressant mechanisms of the PSD95-nNOS decoupler ZL006 using an innovative integrated metabolomics approach.
Institute
Nanjing University of Science & Technology
DepartmentCenter of Molecular Metabolism
Last NameHu
First NameYudie
AddressNanjing University of Science and Technology
Emailhuyudie@njust.edu.cn
Phone+8618759270506
Submit Date2023-11-08
Raw Data AvailableYes
Raw Data File Type(s)mzML
Analysis Type DetailLC-MS
Release Date2023-11-28
Release Version1
Yudie Hu Yudie Hu
https://dx.doi.org/10.21228/M8ZT64
ftp://www.metabolomicsworkbench.org/Studies/ application/zip

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN004876 AN004877
Analysis type MS MS
Chromatography type Reversed phase Reversed phase
Chromatography system Shimadzu 20AD Shimadzu 20AD
Column Waters ACQUITY UPLC BEH C18 (100 x 2.1mm,1.7um) Waters ACQUITY UPLC BEH C18 (100 x 2.1mm,1.7um)
MS Type ESI ESI
MS instrument type Triple TOF Triple TOF
MS instrument name ABI Sciex 5600+ TripleTOF ABI Sciex 5600+ TripleTOF
Ion Mode POSITIVE NEGATIVE
Units log2(peak area) log2 (peak area)

MS:

MS ID:MS004620
Analysis ID:AN004876
Instrument Name:ABI Sciex 5600+ TripleTOF
Instrument Type:Triple TOF
MS Type:ESI
MS Comments:Data was collected in ESI positive ionization mode. The conditions of the ESI source were set as follows: nitrogen was used as nebulizer gas and auxiliary gas, gas 1 (GS1) 55 psi; auxiliary gas (GS2), 55 psi; curtain gas, 35 psi; ion source temperature, 550°C; spray voltage, 5500 V (+). In TOF MS-IDA-MS/MS acquisition, the TOF MS mass scanning range was 100-1250 m/z, and the accumulation time was set to 0.10 s/spectrum. The product ion scanning mass range was 50-1250 m/z, and the accumulation time was set to 0.05 s/spectrum. Independent analysis (IDA) mode was used with high sensitivity mode for product ion scanning. For better spectrum quality in IDA mode, the parameters were set as follows: declustering potential -80 V, collision energy -35 ± 15eV, ion intensity not less than 100 cps, isotopes excluded within 4 Da, ion tolerance 50 mDa, maximum 10 candidate ions monitored per cycle, dynamic background subtraction turned on to improve sensitivity for low abundance or trace analytes. External calibration was performed every 6 samples for TOF MS and TOF MS/MS automatic calibration.
Ion Mode:POSITIVE
  
MS ID:MS004621
Analysis ID:AN004877
Instrument Name:ABI Sciex 5600+ TripleTOF
Instrument Type:Triple TOF
MS Type:ESI
MS Comments:Data was collected in ESI negative ionization mode. The conditions of the ESI source were set as follows: nitrogen was used as nebulizer gas and auxiliary gas, gas 1 (GS1) 55 psi; auxiliary gas (GS2), 55 psi; curtain gas, 35 psi; ion source temperature, 550°C; spray voltage, -4500 V (-). In TOF MS-IDA-MS/MS acquisition, the TOF MS mass scanning range was 100-1250 m/z, and the accumulation time was set to 0.10 s/spectrum. The product ion scanning mass range was 50-1250 m/z, and the accumulation time was set to 0.05 s/spectrum. Independent analysis (IDA) mode was used with high sensitivity mode for product ion scanning. For better spectrum quality in IDA mode, the parameters were set as follows: declustering potential -80 V, collision energy -35 ± 15eV, ion intensity not less than 100 cps, isotopes excluded within 4 Da, ion tolerance 50 mDa, maximum 10 candidate ions monitored per cycle, dynamic background subtraction turned on to improve sensitivity for low abundance or trace analytes. External calibration was performed every 6 samples for TOF MS and TOF MS/MS automatic calibration.
Ion Mode:NEGATIVE