This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR001366. The data can be accessed directly via it's Project DOI: 10.21228/M85115 This work is supported by NIH grant, U2C- DK119886.
See: https://www.metabolomicsworkbench.org/about/howtocite.php
This study contains a large results data set and is not available in the mwTab file. It is only available for download via FTP as data file(s) here.
Study ID | ST002153 |
Study Title | Data from plasma metabolome analysis of APP-KI and Wild type mice treated with B. breve MCC1274 |
Study Summary | Recently, we showed that administration of B. breve MCC1274 reduced amyloid-beta production, inhibited microglial activation, and suppressed inflammatory responses in the brains of APP knock-in (AppNL-G-F) mice. To elucidate the mechanism of action of this probiotic strain in an Alzheimer's disease-like model, we orally fed 3-month-old mice with B. breve MCC1274 or saline for 4 months and comprehensively investigated metabolites in plasma using CE-FTMS and LC-TOFMS. |
Institute | Morinaga milk industry CO., LTD. |
Department | Next generation science institute |
Laboratory | Frontier research section |
Last Name | Ohno |
First Name | Kazuya |
Address | 1-83 5-Chome Higashihara, Zama-city, Kanagawa-Pref. Japan |
kazuya-oono443@morinagamilk.co.jp | |
Phone | 81462523067 |
Submit Date | 2022-04-18 |
Analysis Type Detail | LC-MS |
Release Date | 2022-10-03 |
Release Version | 1 |
Select appropriate tab below to view additional metadata details:
Combined analysis:
Analysis ID | AN003526 | AN003527 |
---|---|---|
Analysis type | MS | MS |
Chromatography type | Normal phase | Reversed phase |
Chromatography system | Agilent 1260 | Agilent 1200 |
Column | fused silica capillary (50 μm i.d. × 80 cm total length; Polymicro Technologies, Inc., Phoenix, AZ) | ODS |
MS Type | ESI | ESI |
MS instrument type | Orbitrap | TOF |
MS instrument name | Thermo Q Exactive Plus Orbitrap | Agilent 6210 TOF |
Ion Mode | UNSPECIFIED | UNSPECIFIED |
Units | peak area | peak area |
MS:
MS ID: | MS003284 |
Analysis ID: | AN003526 |
Instrument Name: | Thermo Q Exactive Plus Orbitrap |
Instrument Type: | Orbitrap |
MS Type: | ESI |
MS Comments: | The spectrometer was scanned from m/z 60 to 900 in positive mode, and from m/z 70 to 1,050 in negative mode |
Ion Mode: | UNSPECIFIED |
MS ID: | MS003285 |
Analysis ID: | AN003527 |
Instrument Name: | Agilent 6210 TOF |
Instrument Type: | TOF |
MS Type: | ESI |
MS Comments: | The spectrometer was scanned from m/z 50 to 1,000 and peaks were extracted using MasterHands, automatic integration software (Keio University, Tsuruoka, Yamagata, Japan) |
Ion Mode: | UNSPECIFIED |