Summary of Study ST002584

This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR001664. The data can be accessed directly via it's Project DOI: 10.21228/M8MH79 This work is supported by NIH grant, U2C- DK119886.

See: https://www.metabolomicsworkbench.org/about/howtocite.php

Perform statistical analysis  |  Show all samples  |  Show named metabolites  |  Download named metabolite data  
Download mwTab file (text)   |  Download mwTab file(JSON)
Study IDST002584
Study TitleMetabolomics analysis of ALDH1L1-expressing HuH7 cell lines.
Study SummaryOne-carbon metabolism is utilized for the de novo synthesis of purines. Given that tumor cells require large amounts of nucleotides, they are highly dependent on one-carbon metabolism. Among the one-carbon-metabolizing enzymes, the aldehyde dehydrogenase 1 family member L1 (ALDH1L1), which catalyzes 10-formyltetrahydrofolate to tetrahydrofolate, is considered a tumor suppressor gene, as its expression is reported to be attenuated or diminished in hepatocellular carcinoma. To clarify the effect of ALDH1L1 expression, we generated control and ALDH1L1-expressing HuH-7 (H7-1L1) cells, and measured the amounts of intracellular metabolites in both control and ALDH1L1-expressing by CE-TOFMS analysis.
Institute
Tohoku Medical and Pharmaceutical University
Last NameSasaki
First NameMasato
Address4-4-1 Komatsushima, Aoba-ku, Sendai, Miyagi, 981-8558, Japan
Emailmsasaki@tohoku-mpu.ac.jp
Phone+81-22-727-0132
Submit Date2023-04-21
Raw Data AvailableYes
Raw Data File Type(s)mzML
Analysis Type DetailLC-MS
Release Date2023-05-01
Release Version1
Masato Sasaki Masato Sasaki
https://dx.doi.org/10.21228/M8MH79
ftp://www.metabolomicsworkbench.org/Studies/ application/zip

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN004255 AN004256
Analysis type MS MS
Chromatography type CE CE
Chromatography system Agilent CE Agilent CE
Column Agilent Fused silica capillary (80cm x 50um) Agilent Fused silica capillary (80cm x 50um)
MS Type ESI ESI
MS instrument type Other Other
MS instrument name Agilent CE-TOFMS Agilent CE-TOFMS
Ion Mode POSITIVE NEGATIVE
Units Relative Area relative area

MS:

MS ID:MS004002
Analysis ID:AN004255
Instrument Name:Agilent CE-TOFMS
Instrument Type:Other
MS Type:ESI
MS Comments:The spectrometer was scanned from m/z 50 to 1,000. Peaks were extracted using automatic integration software MasterHands (ver.2.16.0.15 Keio University). Signal peaks corresponding to isotopomers, adduct ions, and other product ions of known metabolites were excluded, and remaining peaks were annotated with putative metabolites from the HMT metabolite database based on their migration time and m/z values. Peak areas were normalized to internal standards and sample amounts.
Ion Mode:POSITIVE
  
MS ID:MS004003
Analysis ID:AN004256
Instrument Name:Agilent CE-TOFMS
Instrument Type:Other
MS Type:ESI
MS Comments:The spectrometer was scanned from m/z 50 to 1,000. Peaks were extracted using automatic integration software MasterHands (ver.2.16.0.15 Keio University). Signal peaks corresponding to isotopomers, adduct ions, and other product ions of known metabolites were excluded, and remaining peaks were annotated with putative metabolites from the HMT metabolite database based on their migration time and m/z values. Peak areas were normalized to internal standards and sample amounts.
Ion Mode:NEGATIVE
  logo